| Operation temperature |
-20 °C to +70 °C / -4 °F to +158 °F |
| Temperature cycling acceptance criteria |
Δα ≤ 0,15 dB, reversible |
| Temperature cycling |
-20 °C +70 °C / -4 °F +158 °F |
| Temperature cycling - reversible test method |
IEC 60794-1-22:F1 |
| Temperature cycling test method |
IEC 60794-1-22:F1 |
| Temperature cycling - reversible |
-25 °C +70 °C / -13 °F +158 °F |
| Transport / store temperature |
-25 °C to +70 °C / -13 °F to +158 °F |
| Crush resistance - short term |
2000 N/100mm |
| Tensile performance - during installation |
300 N |
| Tensile performance - during installation acceptance criteria |
Δα ≤ 0,05 dB |
| Tensile Performance during Installation TestMethod |
IEC 60794-1-21:E1 |
| Repeated bending acceptance criteria |
no damage |
| Repeated bending test method |
EN 60794-1-21:E6 |
| Repeated bending |
R=20 x cable diameter, 25 cycles |
| Cable bend - acceptance criteria |
Δα ≤ 0,05 dB after test, no damage |
| Torsion |
L = 1 m, rotation angle ±180°, 10 cycles |
| Torsion acceptance criteria |
no damage |
| Impact resistance acceptance criteria |
Δα ≤ 0,05 dB after test, no damage |
| Torsion test method |
IEC 60794-1-21:E7 |
| Impact resistance |
10 Nm, 3 impacts, d=20 mm, R=300 mm |
| Crush resistance - long term acceptance criteria |
Δα ≤ 0,05 dB prior release, no damage |
| Tensile performance - in service acceptance criteria |
Δα ≤ 0,05 dB after test |
| Tensile performance - in service test method |
IEC 60794-1-21:E1 |
| Tensile performance - in service |
1000 N |
| Cable weight |
29.0 kg/km / 19 lbs/1000ft |
| Fiber type |
OM1 |
| Cable type |
Central loose tube cable |
| Jacket material |
UV stable LDPE |
| Fiber Count |
8 |
| CPR classification |
Fca |
| Armour |
Rodent protection |
| Fiber color coding |
1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink |
| RoHS |
Pass |
| Sheath marking |
Ink-Jet, white |
| Cable version |
n.a. |
| Application |
outdoor use |
| Loose tube diameter [mm] |
2.8 |