Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x12-fibers OM5 (R859104)

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x12-fibers OM5 (R859104)

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x12-fibers OM5 (R859104)

Артикул: R859104 Категорія:

Non-metallic central loose tube cable with improved rodent protection. With up to 12 fibers maximum, suitable for indoor or outdoor duct installation.

Technical Data

DESCRIPTIONVALUE/VALUE RANGE
Cable type

Central loose tube cable

Jacket material

UV stable FRLSZH

CPR classificationDca
Armour

Intensified rodent protection

Fiber type

OM5

Fiber Count12
Application

universal-use

Cable family codeUT1GF
DIN/VDE CodeU-DQ(BN)H wbg
DoP no.:D9013
Loose-tube count1
Fiber count per tube12
Loose tube nominal diameter [mm]2.3 mm
Outer jacket nominal thickness [mm]1.1 mm
Cable outer diameter [mm]6.2 mm
Cable version

n.a

Standard put-up length on drum2100 m ± 5%
CPR classification detailDca-s2,d1,a1

Mechanical Data

DESCRIPTIONVALUE/VALUE RANGE
Cable weight45.0 kg/km / 30 lbs/1000ft
Tensile performance - in service

600 N

Tensile performance - in service test method

EN 60794-1-21:E1

Tensile performance - in service acceptance criteria

Δα ≤ 0,05 dB

Tensile performance - during installation

1800 N

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Crush resistance - long term

1000 N/100mm

Crush resistance - long term test method

IEC 60794-1-21:E3A

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Impact resistance

10 Nm, 3 impacts, d=20 mm, R=300 mm

Impact resistance test method

IEC 60794-1-21:E4

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion test method

IEC 60794-1-21:E7

Torsion acceptance criteria

no damage

Cable bend

R=20 x cable diameter, 4 turns, 3 cycles

Cable bend - test method

IEC 60794-1-21:E11A

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Repeated bending

R=20 x cable diameter, 25 cycles

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending acceptance criteria

no damage

Climatic Data

DESCRIPTIONVALUE/VALUE RANGE
Temperature cycling-30 °C 70 °C / -22 °F +158 °F
Temperature cycling - reversible-35 °C 70 °C / -31 °F +158 °F
Installation temperature-5 °C +50 °C / +23 °F +122 °F
Operation temperature-30 °C to 70 °C / -22 °F to +158 °F
Transport / store temperature-35 °C to 70 °C / -31 °F to +158 °F