Front panel with staggered arrangement of adapters.
19" 1U slide-in unit, splice tray plate with 2 splice trays radius 40 mm, fastening material, labeling strips and installation manual
Front panel equipped with adapters and pigtails
Delta insertion loss: ≤ 0.2 dB, testing method acc. to IEC 61300-3-4
Mating cycles: min. 500
Pull-out force: min. 70 N
Assembled with 12 x
Pigtails with semi-tight buffer PA/PBT, Ø 0.9 mm, color in acc. with color code DIN/VDE 0888,singlemode G652.D 9/125 µm (OS1, OS2), length 2.5 m. Fitted with LC connector in acc. with IEC 61754-20. Zirconia (ceramic) ferrulewith an angled polish APC 8° endface geometry, connectors tuned in accordance with IEC 61755-3-2 and qualified in acc. with IEC 61753-1 for category U (uncontrolled environment). Green connector housing (singlemode), material PEI / UL 94 V-0, green strain relief and white plastic dust cover.
Optical specifications (random mated):
Performance acc. to IEC 61753-1 (Table A.12):
Insertion loss (IL) Grade C for 97% of the tested specimen: ≤ 0.50 dB / typical ≤ 0.25 dB
Return loss (RL) Grade 1: ≥ 60 dB (typical ≥ 80 dB)
Mechanical specifications:
Mating cycles: delta IL < 0.2 dB after 500 mating cycles
Pull-out force fiber pigtail: ≥ 5 N
Insertion loss (IL) Grade C for 97% of the tested specimen: ≤ 0.50 dB / typical ≤ 0.25 dB
Return loss (RL) Grade 1: ≥ 60 dB (typical ≥ 80 dB)
Mating cycles: delta IL < 0.2 dB after 500 mating cycles
Pull-out force fiber pigtail: ≥ 5 N
Optional:
Visual coding, mechanical coding and lock protection.