Operation temperature | -40 °C to +70 °C / -40 °F to +158 °F |
Temperature cycling acceptance criteria | Δα ≤ 0,05 dB |
Temperature cycling | -40 °C +70 °C / -40 °F +158 °F |
Temperature cycling - reversible acceptance criteria | Δα ≤ 0,15 dB, reversible |
Temperature cycling - reversible test method | IEC 60794-1-22:F1 |
Temperature cycling test method | IEC 60794-1-22:F1 |
Transport / store temperature | -40 °C to +70 °C / -40 °F to +158 °F |
Crush resistance - short term | 4000 N/100mm |
Expected lifetime | min. 30 years |
Tensile performance - during installation acceptance criteria | Δα ≤ 0,05 dB after test |
Repeated bending acceptance criteria | no damage |
Repeated bending test method | IEC 60794-1-21:E6 |
Repeated bending | R=150 mm, 25 cycles |
Cable bend - acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Torsion | L=2 m, rotation angle ±180°,5 cycles |
Torsion acceptance criteria | no damage |
Impact resistance acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Torsion test method | EN 60794-1-21:E7 |
Impact resistance | 10 Nm, 3 impacts, d=20 mm, R=300 mm |
Crush resistance - long term acceptance criteria | Δα ≤ 0,05 dB prior release, no damage |
Tensile performance - in service acceptance criteria | Δα ≤ 0,15 dB |
Tensile performance - in service test method | IEC 60794-1-21:E1 |
Tensile performance - in service | 1600 N (max. allow-able tension) |
Cable weight | 38.0 kg/km / 25 lbs/1000ft |
Fiber type | G.657.A1 |
Cable type | Flat self-supporting LT cable |
Jacket material | UV stable HDPE |
Cable overall diameter | 8.0 x 4.0 mm |
Fiber Count | 8 |
CPR classification | Fca |
Fiber color coding | 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink |
Sheath marking | Ink-Jet, white |
Cable version | ADSS aerial |
Application | outdoor use |
Loose tube diameter [mm] | 1.9 |