The module for the highest standards. Guarantees the best performance reserves for 10G Ethernet cabling and beyond.
The R&M
freenet
Cat. 6
A
shielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions and high bandwidth applications. This high-performance Cat. 6
Amodule is perfect for use in 10 Gigabit Ethernet (10GBASE-T) and future high-speed applications to 500 MHz. Together with Cat.7A installation cables with AWG22 it is «25G Ready» according to TR11801-9905 and allows for 25GBase-T transmission up to 30m.
RJ45 Cat. 6
AISO connection module, shielded, with adapter No.1
EMC cover
Dust cover
Cable tie
Installation instructions
RJ45 connection module of Cat. 6
A
ISO, for the setting up of transmission channels of Class E
A
with up to 4 plugged connections acc. to ISO/IEC 11801, EN 50173-1, (DIN EN 50173-1) and Class F on 2 pairs, complies with Cat. 6
A
requirements of the standards ISO/IEC 11801, EN 50173-1 as well the U.S. standard Cat. 6
Aaccording to TIA/EIA 568.2-D, re-embedded tested in acc. with IEC 60603-7-51 and 60512-27-100, interoperable and backwards compatible with Category 6 and Category 5e.
Suitable for 10GBASE-T applications in acc. with IEEE 802.3™ Section Four up to 500 MHz and 100 m.
Meets the requirements of ISO/IEC TR11801-9905 together with Cat.7A installation cables with AWG22 and allows for 25GBase-T transmission up to 30m.
Tested in line with R&M's manufacturing control, performing 100% inspection.
Compatible with RJ standard plugs (RJ11, RJ12, RJ45), connection withautomatic wire cutting of installation cables AWG 26 – 22 (0.4 mm – 0.65 mm) and flexible cables AWG 26/7 – AWG 22/7 without special tools. X-Separator for individual pair shielding. Parallel pair termination without crossover in acc. with TIA 568-A/B, gold-plated bronze contacts for >1000 mating cycles, IDC contacts with >20 insertion cycles, contact resistance <5 mOhm, dielectric strength >1000 Veff. Supports PoE (IEEE 802.3af), PoEP (IEEE 802.3at), 4PpoE (IEEE 802.3bt) and is compatible to IEC 60512-99-001/002. 90° wire orientation without bending cable. With integral cable strain relief, including dust cover. Shield contacting by patented shield lance with integral cable strain relief, shield material tin-coated bronze, ground contacting through 1 contact finger for flat connectors 4.8 x 0.5 mm.
Material: halogen-free and heavy-metal free in acc. with EU directives RoHS 2.
Connection module Cat. 6
AISO, shielded, with EMC cover, dust cover, adapter No.1, cable tie and installation instructions.
Інструкції з встановлення | Завантажити |