Synergia logo

Central loose tube cable, indoor-use, no armour, FRLSZH sheath - heather-violet, B2ca, 01x04-fibers OM4 (R857780)

Central loose tube cable, indoor-use, no armour, FRLSZH sheath - heather-violet, B2ca, 01x04-fibers OM4 (R857780)

Central loose tube cable, indoor-use, no armour, FRLSZH sheath - heather-violet, B2ca, 01x04-fibers OM4 (R857780)

Артикул: R857780 Категорія:
Environmental Characteristics

Operation temperature

-20 °C to +60 °C / -4 °F to +140 °F

Temperature cycling acceptance criteria

Δα ≤ 0,05 dB

Temperature cycling

-20 °C +60 °C / -4 °F +140 °F

Temperature cycling - reversible acceptance criteria

Δα ≤ 0,15 dB, reversible

Temperature cycling - reversible test method

IEC 60794-1-22:F1

Temperature cycling test method

IEC 60794-1-22:F1

Temperature cycling - reversible

-25 °C +60 °C / -13 °F +140 °F

Transport / store temperature

-25 °C to +60 °C / -13 °F to +140 °F

Mechanical Data

Crush resistance - short term

1000 N/100mm

Tensile performance - during installation

1000 N (5 min.)

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1A

Repeated bending acceptance criteria

no damage

Kink

d=20 x cable diameter

Repeated bending test method

IEC 60794-1-21:E6

Kink acceptance criteria

no kink

Repeated bending

R=10 x cable diameter, 25 cycles, m = 4Kg

Cable bend - acceptance criteria

no fiber breakage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles, F= 20N

Torsion acceptance criteria

no fiber breakage

Impact resistance acceptance criteria

no fiber breakage

Torsion test method

IEC 60794-1-21:E7

Impact resistance

5 Nm, 3 impacts, d=20 mm, R=12,5 mm

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Cable weight

32.0 kg/km / 21 lbs/1000ft

Technical Data

Fiber type

OM4

Cable type

gel-free indoor duct cable

Jacket material

FRLSZH

Fiber Count

4

CPR classification

B2ca

Armour

Rodent protection

Fiber color coding

1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink(ring-marked)

Cable version

gel-free central loose tube

Application

indoor use

Loose tube diameter [mm]

2.4

Prod

Маєте питання щодо товару, звертайтесь до нас:

 

+380 44 2011900
info@synergia.ua

earthmagnifiercrossmenuchevron-right