| Operation temperature | 
 -20 °C to +60 °C / -4 °F to +140 °F  | 
| Temperature cycling acceptance criteria | 
 Δα ≤ 0,05 dB  | 
| Temperature cycling | 
 -20 °C +60 °C / -4 °F +140 °F  | 
| Temperature cycling - reversible acceptance criteria | 
 Δα ≤ 0,15 dB, reversible  | 
| Temperature cycling - reversible test method | 
 IEC 60794-1-22:F1  | 
| Temperature cycling test method | 
 IEC 60794-1-22:F1  | 
| Temperature cycling - reversible | 
 -25 °C +60 °C / -13 °F +140 °F  | 
| Transport / store temperature | 
 -25 °C to +60 °C / -13 °F to +140 °F  | 
| Crush resistance - short term | 
 1000 N/100mm  | 
| Tensile performance - during installation | 
 1000 N (5 min.)  | 
| Tensile performance - during installation acceptance criteria | 
 Δα ≤ 0,05 dB after test  | 
| Tensile Performance during Installation TestMethod | 
 IEC 60794-1-21:E1A  | 
| Repeated bending acceptance criteria | 
 no damage  | 
| Kink | 
 d=20 x cable diameter  | 
| Repeated bending test method | 
 IEC 60794-1-21:E6  | 
| Kink acceptance criteria | 
 no kink  | 
| Repeated bending | 
 R=10 x cable diameter, 25 cycles, m = 4Kg  | 
| Cable bend - acceptance criteria | 
 no fiber breakage  | 
| Torsion | 
 L = 1 m, rotation angle ±180°, 10 cycles, F= 20N  | 
| Torsion acceptance criteria | 
 no fiber breakage  | 
| Impact resistance acceptance criteria | 
 no fiber breakage  | 
| Torsion test method | 
 IEC 60794-1-21:E7  | 
| Impact resistance | 
 5 Nm, 3 impacts, d=20 mm, R=12,5 mm  | 
| Crush resistance - long term acceptance criteria | 
 Δα ≤ 0,05 dB prior release, no damage  | 
| Cable weight | 
 32.0 kg/km / 21 lbs/1000ft  | 
| Fiber type | 
 OM3  | 
| Cable type | 
 gel-free indoor duct cable  | 
| Jacket material | 
 FRLSZH  | 
| Fiber Count | 
 6  | 
| CPR classification | 
 B2ca  | 
| Armour | 
 Rodent protection  | 
| Fiber color coding | 
 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink(ring-marked)  | 
| Cable version | 
 gel-free central loose tube  | 
| Application | 
 indoor use  | 
| Loose tube diameter [mm] | 
 2.4  |