Synergia logo

Central loose tube cable, fire-resistant, universal-use, FRLSZH sheath - green, Dca, 01x12-fibers G652.D (R855949)

Central loose tube cable, fire-resistant, universal-use, FRLSZH sheath - green, Dca, 01x12-fibers G652.D (R855949)

Central loose tube cable, fire-resistant, universal-use, FRLSZH sheath - green, Dca, 01x12-fibers G652.D (R855949)

Артикул: R855949 Категорія:
Environmental Characteristics

Operation temperature

-30 °C to +70 °C / -22 °F to +158 °F

Temperature cycling acceptance criteria

Δα ≤ 0,05 dB

Temperature cycling

-30 °C +70 °C / -22 °F +158 °F

Temperature cycling - reversible acceptance criteria

Δα ≤ 0,15 dB, reversible

Temperature cycling - reversible test method

IEC 60794-1-22:F1

Temperature cycling test method

IEC 60794-1-22:F1

Temperature cycling - reversible

-35 °C +70 °C / -31 °F +158 °F

Transport / store temperature

-35 °C to +70 °C / -31 °F to +158 °F

Mechanical Data

Crush resistance - short term

2000 N/100mm

Tensile performance - during installation

2000 N

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1

Repeated bending acceptance criteria

no damage

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending

R=20 x cable diameter, 25 cycles

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion acceptance criteria

no damage

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion test method

IEC 60794-1-21:E7

Impact resistance

10 Nm, 3 impacts, d=20 mm, R=300 mm

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Tensile performance - in service acceptance criteria

Δα ≤ 0,05 dB

Tensile performance - in service test method

IEC 60794-1-21:E1

Tensile performance - in service

800 N

Cable weight

58.0 kg/km / 39 lbs/1000ft

Technical Data

Fiber type

G.652.D

Cable type

Central loose tube cable

Jacket material

UV stable FRLSZH

Fiber Count

12

CPR classification

Dca

Armour

Rodent protection

Fire resistance

Pass

Fire resistance test method

EN 60331-25 (180 min at 750°C)

Flammability - vertical cable bundle test method

IEC 60332-3-22

Flammability - vertical single cable test method

IEC 60332-1-2

Halogen free, acid gases

Pass

Halogen free, Acid gases test method

EN 60754-2

Sheath marking

Ink-Jet, black

Smoke density

Pass

Smoke density test method

EN 61034-1, EN 61034-2

Cable version

Fire-resistant

Loose tube diameter [mm]

2.3

Prod

Маєте питання щодо товару, звертайтесь до нас:

 

+380 44 2011900
info@synergia.ua

ЗАПИТАННЯ:
earthmagnifiercrossmenuchevron-right