Synergia logo

Installation Cables

Central loose tube cable, outdoor-use, CSTA - steel tape armour, HDPE sheath - black, 01x08-fibers OM4 (R855779)

Environmental Characteristics Operation temperature 20 °C to 70 °C / +68 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, outdoor-use, CSTA - steel tape armour, HDPE sheath - black, 01x12-fibers G652.D (R855726)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, outdoor-use, CSTA - steel tape armour, HDPE sheath - black, 01x12-fibers G652.D (R855785)

Environmental Characteristics Operation temperature 20 °C to 70 °C / +68 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, outdoor-use, CSTA - steel tape armour, HDPE sheath - black, 01x12-fibers G657.A1 (R855731)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, outdoor-use, CSTA - steel tape armour, HDPE sheath - black, 01x12-fibers G657.A1 (R855789)

Environmental Characteristics Operation temperature 20 °C to 70 °C / +68 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, outdoor-use, CSTA - steel tape armour, HDPE sheath - black, 01x12-fibers OM2 (R855713)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, outdoor-use, CSTA - steel tape armour, HDPE sheath - black, 01x12-fibers OM3 (R855718)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, outdoor-use, CSTA - steel tape armour, HDPE sheath - black, 01x12-fibers OM3 (R855775)

Environmental Characteristics Operation temperature 20 °C to 70 °C / +68 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]
earthmagnifiercrossmenuchevron-downchevron-rightarrow-right