Synergia logo

Fiber Optics

Central loose tube cable, indoor-use, no armour, FRLSZH sheath - orange, B2ca, 01x16-fibers OM2 (R857772)

Environmental Characteristics Operation temperature -20 °C to +60 °C / -4 °F to +140 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +60 °C / -4 °F +140 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, indoor-use, no armour, FRLSZH sheath - orange, B2ca, 01x24-fibers OM2 (R857773)

Environmental Characteristics Operation temperature -20 °C to +60 °C / -4 °F to +140 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +60 °C / -4 °F +140 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, indoor-use, no armour, FRLSZH sheath - turquoise, B2ca, 01x04-fibers OM3 (R857774)

Environmental Characteristics Operation temperature -20 °C to +60 °C / -4 °F to +140 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +60 °C / -4 °F +140 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, indoor-use, no armour, FRLSZH sheath - turquoise, B2ca, 01x06-fibers OM3 (R857775)

Environmental Characteristics Operation temperature -20 °C to +60 °C / -4 °F to +140 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +60 °C / -4 °F +140 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, indoor-use, no armour, FRLSZH sheath - turquoise, B2ca, 01x08-fibers OM3 (R857776)

Environmental Characteristics Operation temperature -20 °C to +60 °C / -4 °F to +140 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +60 °C / -4 °F +140 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, indoor-use, no armour, FRLSZH sheath - turquoise, B2ca, 01x12-fibers OM3 (R857777)

Environmental Characteristics Operation temperature -20 °C to +60 °C / -4 °F to +140 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +60 °C / -4 °F +140 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, indoor-use, no armour, FRLSZH sheath - turquoise, B2ca, 01x16-fibers OM3 (R857778)

Environmental Characteristics Operation temperature -20 °C to +60 °C / -4 °F to +140 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +60 °C / -4 °F +140 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, indoor-use, no armour, FRLSZH sheath - turquoise, B2ca, 01x24-fibers OM3 (R857779)

Environmental Characteristics Operation temperature -20 °C to +60 °C / -4 °F to +140 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +60 °C / -4 °F +140 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]
earthmagnifiercrossmenuchevron-downchevron-rightarrow-right