Synergia logo

Misc

LT-Kabel-I-12-G657A2-Cca (R844629)

Environmental Characteristics Operation temperature -25 °C to +60 °C / -13 °F to +140 °F Water penetration L = 3 m, h = 1 m, 24 h Water penetration test method IEC 60794-1-22:F5B Water penetration acceptance criteria no water leakage Transport / store temperature -40 °C to +60 °C / -40 °F to +140 °F […]

LT-Kabel-I-12-OM4-Cca (R844625)

Environmental Characteristics Operation temperature -25 °C to +60 °C / -13 °F to +140 °F Water penetration L = 3 m, h = 1 m, 24 h Water penetration test method IEC 60794-1-22:F5B Water penetration acceptance criteria no water leakage Transport / store temperature -40 °C to +60 °C / -40 °F to +140 °F […]

LT-Kabel-I-24-G657A2-Cca (R844630)

Environmental Characteristics Operation temperature -25 °C to +60 °C / -13 °F to +140 °F Water penetration L = 3 m, h = 1 m, 24 h Water penetration test method IEC 60794-1-22:F5B Water penetration acceptance criteria no water leakage Transport / store temperature -40 °C to +60 °C / -40 °F to +140 °F […]

LT-Kabel-I-24-OM4-Cca (R844626)

Environmental Characteristics Operation temperature -25 °C to +60 °C / -13 °F to +140 °F Water penetration L = 3 m, h = 1 m, 24 h Water penetration test method IEC 60794-1-22:F5B Water penetration acceptance criteria no water leakage Transport / store temperature -40 °C to +60 °C / -40 °F to +140 °F […]

LT-Kabel-I-4-G657A2-Cca (R844627)

Environmental Characteristics Operation temperature -25 °C to +60 °C / -13 °F to +140 °F Water penetration L = 3 m, h = 1 m, 24 h Water penetration test method IEC 60794-1-22:F5B Water penetration acceptance criteria no water leakage Transport / store temperature -40 °C to +60 °C / -40 °F to +140 °F […]

LT-Kabel-I-4-OM4-Cca (R844134)

Environmental Characteristics Operation temperature -25 °C to +60 °C / -13 °F to +140 °F Water penetration L = 3 m, h = 1 m, 24 h Water penetration test method IEC 60794-1-22:F5B Water penetration acceptance criteria no water leakage Transport / store temperature -40 °C to +60 °C / -40 °F to +140 °F […]

LT-Kabel-I-8-G657A2-Cca (R844628)

Environmental Characteristics Operation temperature -25 °C to +60 °C / -13 °F to +140 °F Water penetration L = 3 m, h = 1 m, 24 h Water penetration test method IEC 60794-1-22:F5B Water penetration acceptance criteria no water leakage Transport / store temperature -40 °C to +60 °C / -40 °F to +140 °F […]

LT-Kabel-I-8-OM4-Cca (R844135)

Environmental Characteristics Operation temperature -25 °C to +60 °C / -13 °F to +140 °F Water penetration L = 3 m, h = 1 m, 24 h Water penetration test method IEC 60794-1-22:F5B Water penetration acceptance criteria no water leakage Transport / store temperature -40 °C to +60 °C / -40 °F to +140 °F […]
earthmagnifiercrossmenuchevron-downchevron-rightarrow-right