| Crush resistance - short term | 2000 N/100mm |
| Tensile performance - during installation | 2000 N |
| Tensile performance - during installation acceptance criteria | Δα ≤ 0,05 dB after test |
| Tensile Performance during Installation TestMethod | IEC 60794-1-21:E1 |
| Repeated bending acceptance criteria | no damage |
| Repeated bending test method | IEC 60794-1-21:E6 |
| Repeated bending | R=20 x cable diameter, 25 cycles |
| Cable bend - acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
| Torsion | L = 1 m, rotation angle ±180°, 10 cycles |
| Torsion acceptance criteria | no damage |
| Impact resistance acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
| Impact resistance | 10 Nm, 3 impacts, d=20 mm, R=300 mm |
| Crush resistance - long term acceptance criteria | Δα ≤ 0,05 dB prior release, no damage |
| Tensile performance - in service acceptance criteria | Δα ≤ 0,05 dB |
| Tensile performance - in service test method | IEC 60794-1-21:E1 |
| Tensile performance - in service | 800 N |
| Cable weight | 68.0 kg/km / 46 lbs/1000ft |