Synergia logo

Central loose tube cable, outdoor-use, CSTA - steel tape armour, HDPE sheath - black, 01x08-fibers OM2 (R855712)

Central loose tube cable, outdoor-use, CSTA - steel tape armour, HDPE sheath - black, 01x08-fibers OM2 (R855712)

Central loose tube cable, outdoor-use, CSTA - steel tape armour, HDPE sheath - black, 01x08-fibers OM2 (R855712)

Артикул: R855712 Категорія:
Environmental Characteristics

Operation temperature

-20 °C to +70 °C / -4 °F to +158 °F

Temperature cycling acceptance criteria

Δα ≤ 0,05 dB

Temperature cycling

-20 °C +70 °C / -4 °F +158 °F

Temperature cycling - reversible acceptance criteria

Δα ≤ 0,15 dB, reversible

Temperature cycling - reversible test method

IEC 60794-1-22:F1

Temperature cycling test method

IEC 60794-1-22:F1

Temperature cycling - reversible

-30 °C +70 °C / -22 °F +158 °F

Transport / store temperature

-30 °C to +70 °C / -22 °F to +158 °F

Mechanical Data

Crush resistance - short term

5000 N/100mm

Tensile performance - during installation

1500 N

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1

Repeated bending acceptance criteria

no damage

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending

R=20 x cable diameter, 25 cycles

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion acceptance criteria

no damage

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion test method

IEC 60794-1-21:E7

Impact resistance

20 Nm, 3 impacts, d=20 mm, R=300 mm

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Tensile performance - in service acceptance criteria

Δα ≤ 0,05 dB

Tensile performance - in service test method

IEC 60794-1-21:E1

Tensile performance - in service

500 N

Cable weight

70.0 kg/km / 47 lbs/1000ft

Technical Data

Fiber type

OM2

Cable type

Central loose tube cable

Jacket material

UV stable HDPE

Fiber Count

8

CPR classification

Fca

Armour

Corrugated steel tape armoured (CSTA)

Fiber color coding

1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink(ring-marked)

RoHS

Pass

Sheath marking

Ink-Jet, white

Standard put-up length on drum

4100 m ± 5%

Cable version

n.a.

Application

outdoor use

Loose tube diameter [mm]

3

Prod

Маєте питання щодо товару, звертайтесь до нас:

 

+380 44 2011900
info@synergia.ua

earthmagnifiercrossmenuchevron-right