Operation temperature | 20 °C to 70 °C / +68 °F to +158 °F |
Temperature cycling acceptance criteria | Δα ≤ 0,05 dB |
Temperature cycling | -20 °C +70 °C / -4 °F +158 °F |
Temperature cycling - reversible acceptance criteria | Δα ≤ 0,15 dB, reversible |
Temperature cycling - reversible test method | IEC 60794-1-22:F1 |
Temperature cycling test method | IEC 60794-1-22:F1 |
Temperature cycling - reversible | -25 °C +70 °C / -13 °F +158 °F |
Transport / store temperature | -25 °C to +70 °C / -13 °F to +158 °F |
Crush resistance - short term | 5000 N/100mm |
Tensile performance - during installation | 1500 N |
Tensile performance - during installation acceptance criteria | Δα ≤ 0,05 dB after test |
Tensile Performance during Installation TestMethod | IEC 60794-1-21:E1 |
Repeated bending acceptance criteria | no damage |
Repeated bending test method | IEC 60794-1-21:E6 |
Repeated bending | R=20 x cable diameter, 25 cycles |
Cable bend - acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Torsion | L = 1 m, rotation angle ±180°, 10 cycles |
Torsion acceptance criteria | no damage |
Impact resistance acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Torsion test method | EN 60794-1-21:E7 |
Impact resistance | 20 Nm, 3 impacts, d=20 mm, R=300 mm |
Crush resistance - long term acceptance criteria | Δα ≤ 0,05 dB prior release, no damage |
Tensile performance - in service acceptance criteria | Δα ≤ 0,05 dB |
Tensile performance - in service test method | IEC 60794-1-21:E1 |
Tensile performance - in service | 500 N |
Cable weight | 100.0 kg/km / 67 lbs/1000ft |
Fiber type | OM4 |
Cable type | Central loose tube cable |
Cable design | Double jacket |
Jacket material | UV stable HDPE |
Fiber Count | 12 |
Inner jacket nominal thickness [mm] | 0.8000000000 mm |
CPR classification | Fca |
Armour | Corrugated steel tape armoured (CSTA) |
Fiber color coding | 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink(ring-marked) |
RoHS | Pass |
Sheath marking | Ink-Jet, white |
Standard put-up length on drum | 4100 m ± 5% |
Cable version | n.a. |
Application | outdoor use |
Loose tube diameter [mm] | 3.1 |