Crush resistance - short term | 500 N/100mm |
Tensile performance - during installation | 150 N |
Tensile performance - during installation acceptance criteria | Δα ≤ 0,05 dB after test |
Tensile Performance during Installation TestMethod | EN 60794-1-21:E1 |
Repeated bending acceptance criteria | no damage |
Repeated bending test method | IEC 60794-1-21:E6 |
Repeated bending | R=40 x cable diameter, 25 cycles |
Cable bend - acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Torsion | L = 1 m, rotation angle ±180°, 10 cycles |
Torsion acceptance criteria | no damage |
Impact resistance acceptance criteria | Δα ≤ 0,1 dB after test, no damage |
Impact resistance | 1 Nm, 3 impacts, d=20 mm, R=300 mm |
Cable weight | 11.0 kg/km / 7 lbs/1000ft |