| Operation temperature | -20 °C to +70 °C / -4 °F to +158 °F |
| Water penetration | L = 3 m, h = 1 m, 24 h |
| Water penetration test method | IEC 60794-1-22:F5B |
| Water penetration acceptance criteria | no water leakage |
| Temperature cycling acceptance criteria | Δα ≤ 0,05 dB |
| Temperature cycling | -20 °C +70 °C / -4 °F +158 °F |
| Temperature cycling - reversible acceptance criteria | Δα ≤ 0,15 dB, reversible |
| Temperature cycling - reversible test method | IEC 60794-1-22:F1 |
| Temperature cycling test method | IEC 60794-1-22:F1 |
| Temperature cycling - reversible | -25 °C +70 °C / -13 °F +158 °F |
| Transport / store temperature | -25 °C to +70 °C / -13 °F to +158 °F |
| Crush resistance - short term | 4000 N/100mm |
| Tensile performance - during installation | 2000 N |
| Tensile performance - during installation acceptance criteria | Δα ≤ 0,05 dB after test |
| Tensile Performance during Installation TestMethod | IEC 60794-1-21:E1 |
| Repeated bending acceptance criteria | no damage |
| Repeated bending test method | IEC 60794-1-21:E6 |
| Repeated bending | R=10 x cable diameter, 25 cycles, m = 4Kg |
| Cable bend - acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
| Torsion | L = 1 m, rotation angle ±180°, 10 cycles |
| Torsion acceptance criteria | no damage |
| Impact resistance acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
| Torsion test method | IEC 60794-1-21:E7 |
| Impact resistance | 10 Nm, 3 impacts, d=20 mm, R=300 mm |
| Crush resistance - long term acceptance criteria | Δα ≤ 0,05 dB prior release, no damage |
| Tensile performance - in service acceptance criteria | Δα ≤ 0,05 dB |
| Tensile performance - in service test method | IEC 60794-1-21:E1 |
| Tensile performance - in service | 1000 N |
| Cable weight | 32.0 kg/km / 21 lbs/1000ft |
| Fiber type | OM5 |
| Cable type | gel-free, rodent protected, universal duct cable |
| Jacket material | UV stable FRLSZH |
| Fiber Count | 4 |
| CPR classification | Cca |
| Armour | Rodent protection |
| Flammability - vertical single cable test method | IEC 60332-1-2 |
| Halogen free, acid gases | Pass |
| Halogen free, Acid gases test method | IEC 60754-2 |
| Minimum bending radius | no tension - 10 x cable diameter |
| Fiber color coding | 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink |
| RoHS | conform |
| Smoke density | Pass |
| Smoke density test method | IEC 61034-2 |
| Warranty | R&Mfreenet |
| Cable version | gel-free central loose tube |
| Application | universal use |
| Loose tube diameter [mm] | 2.8 |