Synergia logo

Gel-free central loose tube cable, universal-use, imp. rodent protected, FRLSZH sheath - lime-green, Cca, 01x04-fibers OM5 (R870420)

Gel-free central loose tube cable, universal-use, imp. rodent protected, FRLSZH sheath - lime-green, Cca, 01x04-fibers OM5 (R870420)

Gel-free central loose tube cable, universal-use, imp. rodent protected, FRLSZH sheath - lime-green, Cca, 01x04-fibers OM5 (R870420)

Артикул: R870420 Категорія:
Environmental Characteristics

Operation temperature

-20 °C to +70 °C / -4 °F to +158 °F

Water penetration

L = 3 m, h = 1 m, 24 h

Water penetration test method

IEC 60794-1-22:F5B

Water penetration acceptance criteria

no water leakage

Temperature cycling acceptance criteria

Δα ≤ 0,05 dB

Temperature cycling

-20 °C +70 °C / -4 °F +158 °F

Temperature cycling - reversible acceptance criteria

Δα ≤ 0,15 dB, reversible

Temperature cycling - reversible test method

IEC 60794-1-22:F1

Temperature cycling test method

IEC 60794-1-22:F1

Temperature cycling - reversible

-25 °C +70 °C / -13 °F +158 °F

Transport / store temperature

-25 °C to +70 °C / -13 °F to +158 °F

Mechanical Data

Crush resistance - short term

4000 N/100mm

Tensile performance - during installation

2000 N

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1

Repeated bending acceptance criteria

no damage

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending

R=10 x cable diameter, 25 cycles, m = 4Kg

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion acceptance criteria

no damage

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion test method

IEC 60794-1-21:E7

Impact resistance

10 Nm, 3 impacts, d=20 mm, R=300 mm

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Tensile performance - in service acceptance criteria

Δα ≤ 0,05 dB

Tensile performance - in service test method

IEC 60794-1-21:E1

Tensile performance - in service

1000 N

Cable weight

32.0 kg/km / 21 lbs/1000ft

Technical Data

Fiber type

OM5

Cable type

gel-free, rodent protected, universal duct cable

Jacket material

UV stable FRLSZH

Fiber Count

4

CPR classification

Cca

Armour

Rodent protection

Flammability - vertical single cable test method

IEC 60332-1-2

Halogen free, acid gases

Pass

Halogen free, Acid gases test method

IEC 60754-2

Minimum bending radius

no tension - 10 x cable diameter

Fiber color coding

1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

RoHS

conform

Smoke density

Pass

Smoke density test method

IEC 61034-2

Warranty

R&Mfreenet

Cable version

gel-free central loose tube

Application

universal use

Loose tube diameter [mm]

2.8

Prod