| Operation temperature | 
 -25 °C to +60 °C / -13 °F to +140 °F  | 
| Water penetration | 
 L = 3 m, h = 1 m, 24 h  | 
| Water penetration test method | 
 IEC 60794-1-22:F5B  | 
| Water penetration acceptance criteria | 
 no water leakage  | 
| Transport / store temperature | 
 -40 °C to +60 °C / -40 °F to +140 °F  | 
| Cable length | 
 2,000 m  | 
| Tensile performance - in service test method | 
 IEC 60794-1-21:E1  | 
| Tensile performance - in service | 
 1000 N  | 
| Conductor type FO | 
 loose tube, gel-filled  | 
| Fiber type | 
 OM3  | 
| Fiber diameter | 
 G50 / 125 µm  | 
| Cable type | 
 Central loose tube cable  | 
| Jacket material | 
 LSZH  | 
| Fiber Count | 
 4  | 
| CPR classification | 
 Cca  | 
| Standard | 
 ISO 11801:2011 EN 50173-1 IEC 60794-2-20 IEC 60332-1-2 IEC 60754-2 IEC 60754-1 IEC 61034-2 CPR fire class: EN50575  | 
| Armour | 
 Waterblocked E-Glass fiber elements  | 
| Application | 
 universal use  | 
| Loose tube diameter [mm] | 
 2.8  |