| Operation temperature |
-25 °C to +60 °C / -13 °F to +140 °F |
| Water penetration |
L = 3 m, h = 1 m, 24 h |
| Water penetration test method |
IEC 60794-1-22:F5B |
| Water penetration acceptance criteria |
no water leakage |
| Transport / store temperature |
-40 °C to +60 °C / -40 °F to +140 °F |
| Cable length |
2,000 m |
| Tensile performance - in service test method |
IEC 60794-1-21:E1 |
| Tensile performance - in service |
1000 N |
| Conductor type FO |
loose tube, gel-filled |
| Fiber type |
G.652.D |
| Fiber diameter |
n.a. |
| Cable type |
Central loose tube cable |
| Jacket material |
LSZH |
| Fiber Count |
12 |
| CPR classification |
Cca |
| Standard |
EN 50173-1 ISO 11801:2011 IEC 60794-2-20 IEC 60332-1-2 IEC 60754-1 IEC 60754-2 IEC 61034-2 CPR fire class: EN50575 |
| Armour |
Waterblocked E-Glass fiber elements |
| Application |
universal use |
| Loose tube diameter [mm] |
2.8 |