| Operation temperature | -20 °C to +60 °C / -4 °F to +140 °F |
| Temperature cycling acceptance criteria | Δα ≤ 0,05 dB |
| Temperature cycling | -20 °C +60 °C / -4 °F +140 °F |
| Temperature cycling - reversible acceptance criteria | Δα ≤ 0,15 dB, reversible |
| Temperature cycling - reversible test method | IEC 60794-1-22:F1 |
| Temperature cycling test method | IEC 60794-1-22:F1 |
| Temperature cycling - reversible | -25 °C +60 °C / -13 °F +140 °F |
| Transport / store temperature | -25 °C to +60 °C / -13 °F to +140 °F |
| Crush resistance - short term | 1000 N/100mm |
| Expected lifetime | min. 30 years |
| Tensile performance - during installation acceptance criteria | Δα ≤ 0,05 dB after test |
| Repeated bending acceptance criteria | no damage |
| Repeated bending test method | IEC 60794-1-21:E6 |
| Repeated bending | R=20 x cable diameter, 25 cycles |
| Cable bend - acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
| Torsion | L=2 m, rotation angle ±180°,5 cycles |
| Torsion acceptance criteria | no damage |
| Impact resistance acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
| Torsion test method | EN 60794-1-21:E7 |
| Impact resistance | 3 Nm, 3 impacts, d=20 mm,R=300 mm |
| Crush resistance - long term acceptance criteria | Δα ≤ 0,05 dB prior release, no damage |
| Tensile performance - in service acceptance criteria | Δα ≤ 0,15 dB |
| Tensile performance - in service test method | IEC 60794-1-21:E1 |
| Tensile performance - in service | 1000 N (max. allow-able tension) |
| Cable weight | 13.0 kg/km / 9 lbs/1000ft |
| Fiber type | G.657.A1 |
| Cable type | MiniCore cable |
| Jacket material | UV stable FRLSZH |
| Fiber Count | 6 |
| CPR classification | Cca |
| Fiber color coding | 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink |
| Sheath marking | Ink-Jet, black |
| Cable version | Aerial drop |
| Application | universal use |