Environmental Characteristics

Operation temperature

-40 °C to +70 °C / -40 °F to +158 °F

Temperature cycling acceptance criteria

Δα ≤ 0,05 dB

Temperature cycling

-40 °C +70 °C / -40 °F +158 °F

Temperature cycling test method

IEC 60794-1-22:F1

Transport / store temperature

-40 °C to +70 °C / -40 °F to +158 °F

Mechanical Data

Crush resistance - short term

2000 N/100mm

Expected lifetime

min. 30 years

Tensile performance - during installation

6000 N

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1

Repeated bending acceptance criteria

no damage

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending

R=20 x cable diameter, 25 cycles

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion acceptance criteria

no damage

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion test method

IEC 60794-1-21:E7

Impact resistance

10 Nm, 3 impacts, d=20 mm, R=300 mm

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Tensile performance - in service acceptance criteria

Δα ≤ 0,05 dB

Tensile performance - in service test method

IEC 60794-1-21:E1

Tensile performance - in service

1800 N

Cable weight

340.0 kg/km / 228 lbs/1000ft

Technical Data

Fiber type

OM3

Cable type

Stranded loose tube cable

Jacket material

UV stable FRLSZH

Fiber Count

144

CPR classification

Fca

Armour

Intensified rodent protection

Fire resistance

Pass

Fire resistance test method

EN 60331-25 (180 min at 750°C)

Flammability - vertical cable bundle test method

IEC 60332-3-22

Flammability - vertical single cable test method

IEC 60332-1-2

Halogen free, acid gases

Pass

Halogen free, Acid gases test method

EN 60754-2

Fiber color coding

1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Sheath marking

Ink-Jet, black

Smoke density

Pass

Smoke density test method

EN 61034-1, EN 61034-2

FRP/coat. CSM nominal thickness [mm]

2.8 / 7.8

Cable version

Fire-resistant

Application

universal use

Loose tube diameter [mm]

2.3

Prod