Synergia logo

Stranded loose tube cable, universal-use, CSTA-steel tape armour, FRLSZH sheath - green, Fca, 04x12-fibers OM3 (R857427)

Stranded loose tube cable, universal-use, CSTA-steel tape armour, FRLSZH sheath - green, Fca, 04x12-fibers OM3 (R857427)

Stranded loose tube cable, universal-use, CSTA-steel tape armour, FRLSZH sheath - green, Fca, 04x12-fibers OM3 (R857427)

Артикул: R857427 Категорія:
Environmental Characteristics

Operation temperature

-40 °C to +70 °C / -40 °F to +158 °F

Temperature cycling acceptance criteria

Δα ≤ 0,05 dB

Temperature cycling

-40 °C +70 °C / -40 °F +158 °F

Temperature cycling test method

IEC 60794-1-22:F1

Transport / store temperature

-40 °C to +70 °C / -40 °F to +158 °F

Mechanical Data

Crush resistance - short term

5000 N/100mm

Expected lifetime

min. 30 years

Tensile performance - during installation

2500 N

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1

Repeated bending acceptance criteria

no damage

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending

R=20 x cable diameter, 25 cycles

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion acceptance criteria

no damage

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion test method

IEC 60794-1-21:E7

Impact resistance

25 Nm, 3 impacts, d=20 mm, R=300 mm

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Tensile performance - in service acceptance criteria

Δα ≤ 0,05 dB

Tensile performance - in service test method

IEC 60794-1-21:E1

Tensile performance - in service

800 N

Cable weight

180.0 kg/km / 121 lbs/1000ft

Technical Data

Fiber type

OM3

Cable type

Stranded loose tube cable

Cable design

Double jacket

Jacket material

UV stable FRLSZH

Fiber Count

48

Inner jacket nominal thickness [mm]

0.9000000000 mm

CPR classification

Eca

Armour

Corrugated steel tape armoured (CSTA)

Flammability - vertical cable bundle test method

IEC 60332-3-22

Flammability - vertical single cable test method

IEC 60332-1-2

Halogen free, acid gases

Pass

Halogen free, Acid gases test method

EN 60754-2

Fiber color coding

1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Sheath marking

Ink-Jet, black

Smoke density

Pass

Smoke density test method

EN 61034-1, EN 61034-2

Standard put-up length on drum

4100 m ± 5%

FRP/coat. CSM nominal thickness [mm]

1.7

Cable version

n.a.

Application

universal use

Loose tube diameter [mm]

1.7

Prod

Маєте питання щодо товару, звертайтесь до нас:

 

+380 44 2011900
info@synergia.ua

earthmagnifiercrossmenuchevron-right