Synergia logo

Installation Cables

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x04-fibers G652.D (R855629)

Environmental Characteristics Operation temperature -30 °C to 70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -30 °C 70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB after test Temperature cycling - reversible test method IEC 60794-1-22:F1 […]

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x04-fibers G657.A1 (R855637)

Environmental Characteristics Operation temperature -30 °C to 70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -30 °C 70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB after test Temperature cycling - reversible test method IEC 60794-1-22:F1 […]

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x04-fibers OM1 (R855600)

Environmental Characteristics Operation temperature -30 °C to 70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -30 °C 70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB after test Temperature cycling - reversible test method IEC 60794-1-22:F1 […]

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x04-fibers OM2 (R855608)

Environmental Characteristics Operation temperature -30 °C to 70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -30 °C 70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB after test Temperature cycling - reversible test method IEC 60794-1-22:F1 […]

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x04-fibers OM3 (R855616)

Environmental Characteristics Operation temperature -30 °C to 70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -30 °C 70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB after test Temperature cycling - reversible test method IEC 60794-1-22:F1 […]

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x04-fibers OM4 (R855622)

Environmental Characteristics Operation temperature -30 °C to 70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -30 °C 70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB after test Temperature cycling - reversible test method IEC 60794-1-22:F1 […]

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x06-fibers G652.D (R855630)

Environmental Characteristics Operation temperature -30 °C to 70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -30 °C 70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB after test Temperature cycling - reversible test method IEC 60794-1-22:F1 […]

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x06-fibers G657.A1 (R855638)

Environmental Characteristics Operation temperature -30 °C to 70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -30 °C 70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB after test Temperature cycling - reversible test method IEC 60794-1-22:F1 […]
earthmagnifiercrossmenuchevron-downchevron-rightarrow-right