Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x08-fibers OM3 (R855618)

Environmental Characteristics Operation temperature -30 °C to 70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -30 °C 70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB after test Temperature cycling - reversible test method IEC 60794-1-22:F1 […]

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x08-fibers OM4 (R855624)

Environmental Characteristics Operation temperature -30 °C to 70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -30 °C 70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB after test Temperature cycling - reversible test method IEC 60794-1-22:F1 […]

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x12-fibers G652.D (R855632)

Environmental Characteristics Operation temperature -30 °C to 70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -30 °C 70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB after test Temperature cycling - reversible test method IEC 60794-1-22:F1 […]

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x12-fibers G657.A1 (R855640)

Environmental Characteristics Operation temperature -30 °C to 70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -30 °C 70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB after test Temperature cycling - reversible test method IEC 60794-1-22:F1 […]

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x12-fibers OM1 (R855603)

Environmental Characteristics Operation temperature -30 °C to 70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -30 °C 70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB after test Temperature cycling - reversible test method IEC 60794-1-22:F1 […]

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x12-fibers OM2 (R855611)

Environmental Characteristics Operation temperature -30 °C to 70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -30 °C 70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB after test Temperature cycling - reversible test method IEC 60794-1-22:F1 […]

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x12-fibers OM3 (R855619)

Environmental Characteristics Operation temperature -30 °C to 70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -30 °C 70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB after test Temperature cycling - reversible test method IEC 60794-1-22:F1 […]

Central loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Dca, 01x12-fibers OM4 (R855625)

Environmental Characteristics Operation temperature -30 °C to 70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -30 °C 70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB after test Temperature cycling - reversible test method IEC 60794-1-22:F1 […]