Synergia logo

Fiber Optics

Central loose tube cable, outdoor-use, no armour, LDPE sheath - black, 01x04-fibers OM3 (R855502)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling test method IEC 60794-1-22:F1 Temperature cycling - reversible -25 °C […]

Central loose tube cable, outdoor-use, no armour, LDPE sheath - black, 01x04-fibers OM4 (R855505)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling test method IEC 60794-1-22:F1 Temperature cycling - reversible -25 °C […]

Central loose tube cable, outdoor-use, no armour, LDPE sheath - black, 01x06-fibers G652.D (R855510)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling test method IEC 60794-1-22:F1 Temperature cycling - reversible -25 °C […]

Central loose tube cable, outdoor-use, no armour, LDPE sheath - black, 01x06-fibers G657.A1 (R855513)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling test method IEC 60794-1-22:F1 Temperature cycling - reversible -25 °C […]

Central loose tube cable, outdoor-use, no armour, LDPE sheath - black, 01x06-fibers OM1 (R855495)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling test method IEC 60794-1-22:F1 Temperature cycling - reversible -25 °C […]

Central loose tube cable, outdoor-use, no armour, LDPE sheath - black, 01x06-fibers OM2 (R855499)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling test method IEC 60794-1-22:F1 Temperature cycling - reversible -25 °C […]

Central loose tube cable, outdoor-use, no armour, LDPE sheath - black, 01x06-fibers OM3 (R855503)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling test method IEC 60794-1-22:F1 Temperature cycling - reversible -25 °C […]

Central loose tube cable, outdoor-use, no armour, LDPE sheath - black, 01x06-fibers OM4 (R855506)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling test method IEC 60794-1-22:F1 Temperature cycling - reversible -25 °C […]
earthmagnifiercrossmenuchevron-downchevron-rightarrow-right