Synergia logo

Fiber Optics

Central loose tube cable, fire-resistant, universal-use, CSTA-steel tape armour, FRLSZH sheath - green, B2ca, 01x04-fibers G652.D (R856028)

Environmental Characteristics Operation temperature -30 °C to +70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -30 °C +70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, fire-resistant, universal-use, CSTA-steel tape armour, FRLSZH sheath - green, B2ca, 01x04-fibers G657.A1 (R856038)

Environmental Characteristics Operation temperature -30 °C to +70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -30 °C +70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, fire-resistant, universal-use, CSTA-steel tape armour, FRLSZH sheath - green, B2ca, 01x04-fibers OM3 (R856009)

Environmental Characteristics Operation temperature -30 °C to +70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -30 °C +70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, fire-resistant, universal-use, CSTA-steel tape armour, FRLSZH sheath - green, B2ca, 01x04-fibers OM4 (R856019)

Environmental Characteristics Operation temperature -30 °C to +70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -30 °C +70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, fire-resistant, universal-use, CSTA-steel tape armour, FRLSZH sheath - green, B2ca, 01x06-fibers G652.D (R856029)

Environmental Characteristics Operation temperature -30 °C to +70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -30 °C +70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, fire-resistant, universal-use, CSTA-steel tape armour, FRLSZH sheath - green, B2ca, 01x06-fibers G657.A1 (R856039)

Environmental Characteristics Operation temperature -30 °C to +70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -30 °C +70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, fire-resistant, universal-use, CSTA-steel tape armour, FRLSZH sheath - green, B2ca, 01x06-fibers OM3 (R856010)

Environmental Characteristics Operation temperature -30 °C to +70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -30 °C +70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, fire-resistant, universal-use, CSTA-steel tape armour, FRLSZH sheath - green, B2ca, 01x06-fibers OM4 (R856020)

Environmental Characteristics Operation temperature -30 °C to +70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -30 °C +70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]
earthmagnifiercrossmenuchevron-downchevron-rightarrow-right