Synergia logo

Central loose tube cable, Micro, outdoor-use, no armour, HDPE sheath - black, 01x02-fibers OM3 (R855474)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, Micro, outdoor-use, no armour, HDPE sheath - black, 01x02-fibers OM4 (R855479)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, Micro, outdoor-use, no armour, HDPE sheath - black, 01x04-fibers G652.D (R855483)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, Micro, outdoor-use, no armour, HDPE sheath - black, 01x04-fibers G657.A1 (R855486)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, Micro, outdoor-use, no armour, HDPE sheath - black, 01x04-fibers OM3 (R855477)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, Micro, outdoor-use, no armour, HDPE sheath - black, 01x04-fibers OM4 (R855480)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, Micro, outdoor-use, no armour, HDPE sheath - black, 01x06-fibers G652.D (R848282)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, Micro, outdoor-use, no armour, HDPE sheath - black, 01x06-fibers G657.A1 (R855487)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]
earthmagnifiercrossmenuchevron-downchevron-rightarrow-right