Synergia logo

Fiber Optics

Central loose tube cable, outdoor-use, SWA-steel wire armour, HDPE sheath - black, 01x24-fibers G657.A1 (R855671)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling test […]

Central loose tube cable, outdoor-use, SWA-steel wire armour, HDPE sheath - black, 01x24-fibers OM3 (R855656)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling test […]

Central loose tube cable, outdoor-use, SWA-steel wire armour, HDPE sheath - black, 01x24-fibers OM4 (R855661)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling test […]

Central loose tube cable, outdoor-use, SWA-steel wire armour, HDPE sheath - black, 01x04-fibers OM3 (R855652)

Environmental Characteristics Operation temperature -20 °C to +70 °C / -4 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -20 °C +70 °C / -4 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,05 dB Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling test […]

Central loose tube cable, universal-use, CSTA - steel tape armour, FRLSZH sheath - green, B2ca, 01x04-fibers G652.D (R855854)

Environmental Characteristics Operation temperature -30 °C to +70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -30 °C +70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, universal-use, CSTA - steel tape armour, FRLSZH sheath - green, B2ca, 01x04-fibers G657.A1 (R855864)

Environmental Characteristics Operation temperature -30 °C to +70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -30 °C +70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, universal-use, CSTA - steel tape armour, FRLSZH sheath - green, B2ca, 01x04-fibers OM3 (R855835)

Environmental Characteristics Operation temperature -30 °C to +70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -30 °C +70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]

Central loose tube cable, universal-use, CSTA - steel tape armour, FRLSZH sheath - green, B2ca, 01x04-fibers OM4 (R855845)

Environmental Characteristics Operation temperature -30 °C to +70 °C / -22 °F to +158 °F Temperature cycling acceptance criteria Δα ≤ 0,05 dB Temperature cycling -30 °C +70 °C / -22 °F +158 °F Temperature cycling - reversible acceptance criteria Δα ≤ 0,15 dB, reversible Temperature cycling - reversible test method IEC 60794-1-22:F1 Temperature cycling […]
earthmagnifiercrossmenuchevron-downchevron-rightarrow-right